732-264-7700
Asphalt Heating
POLY-ONE TANK
Using the Infern-O-Therm Combustion principal, this IOT designed two
pass oil heater is installed into the product tank. This uses all
the BTU's to heat the product. Only the transfer oil jacket and hot
oil coil come in contact with the product allowing the system to be
used with polymers or asphalt. A closed loop hot oil circulation system
is incorporated, preventing coking of the transfer oil as well as
eliminating air and moisture in the system.
Burner range from 275,000 to 900,000 BTU input.
UL approved #2 fuel oil fired burner with 90% efficiency.
Tank is fully insulated with 3" 4 LB density mineral wool with
.024 weatherproof stucco aluminum jacket, mounted on full 15"
x 33.9 lb channel skid. Portable models available.


30,000 gallon portable asphalt tank with Infern-O-Therm thermal fluid
heater mounted on gooseneck.
ONE-PLUS-ONE
CK ONE-PLUS-ONE II is a closed loop hot oil heating system for installation
into a new or existing asphalt storage tank. This unit will provide
heat for other tanks, asphalt plant, pump, piping, silos, and drag
slat. This unit can be installed in both horizontal and vertical
tanks of all sizes.
35,000 gallon 1+1 asphalt
and plant heating system with mounted 3" loading pump

HEATER PERFORMANCE CHART
| ONE-PLUS-ONE
MODEL # |
BTU'S INPUT |
FUEL CONSUMPTION GPH |
| 48/18 |
310,500 |
2.25 |
| 48/100 |
414,000 |
3.00 |
| 150 |
621,000 |
4.50 |
| 200 |
828,000 |
6.0 |
| 300 |
1,380,000 |
10.0 |
| 400 |
2,760,000 |
20.0 |
|
35,000 gallon 1+1 asphalt
and plant heating system with mounted 3" loading pump
|
|
|
|
ADVANTAGES
- Absolutely no coking or hot spots
- The BTU's go into the liquid--not out the stack
- Heats 5,000 or up to multi-million gallon tanks
- Fully automatic
- Extremely low operating costs
- Simple operation
- Rapid temperature recovery
- Virtually maintenance free
|
 |
OPERATING FEATURES
OPERATES ON GAS OR OIL
The One-Plus-One II operates efficiently either on gas,
propane, or No. 2 fuel oil. Conversion from one fuel to
the other is accomplished by a single switch. Special linkage
or air adjustments are not required. Changeovers can even
be done while the system is in full operation.
DIRECT TUBE HEATING
Direct tube heat transfer is the most efficient and economical
method available to heat asphalt. The One-Plus-One II
direct heating system offers both precise temperature
control and even heat distribution characteristics without
flame impingement, hot spots or product degradation.
|
I-O-T TRAIL BURNER
20,000 Gallon Portable Asphalt Heating System
Built to IOT quality standards--using Infern-O-Therm burner
& Firetube system, with 2"-seamless Scavenger pipe coil for
maximum transfer oil capabilities. Designed for ease of installation
in either stationary or portable models, closed loop hot oil
circulation system, w/ Positive Displacement Pump. |
|
TRAILBURNER TANK SPECIFICATIONS
|
Model |
Height |
Width |
Length |
Weight |
Tank Size |
Burner# |
Fuel GPH |
BTU's Input |
Tube Diameter |
Co2 |
Bacharach Smoke Scale |
| TB
105M |
8'9" |
8' |
34' |
8.0
Tons |
10,000
Gals. |
200 |
6.00 |
828,000 |
16" |
12-13% |
0.1 |
| TB
155M |
11'8" |
11'0" |
26' |
9.5
Tons |
15,000
Gals. |
200 |
6.00 |
828,000 |
16" |
12-13% |
0.1 |
| TB
205M |
11'8" |
11'0" |
34' |
11.5
Tons |
20,000
Gals. |
200 |
6.00 |
828,000 |
16" |
12-13% |
0.1 |
| TB
255M |
11'8" |
11'0" |
42' |
14.0
Tons |
25,000
Gals. |
200 |
6.00 |
828,000 |
16" |
12-13% |
0.1 |
| TB
305M |
11'8" |
11'0" |
50' |
17.3
Tons |
30,000
Gals. |
200 |
6.00 |
828,000 |
16" |
12-13% |
0.1 |
|
Standard Circulation System for Trailburner
Scavenger Hot Oil System
|
HE SERIES
- 300,000 to 900,000 BTU Input
- Compact Design for Gooseneck Applications
- Unique Two Pass Design for High Efficiency
- UL Approved Oil or Natural Gas Fired Burner
- Convenient One Hook Up Power Supply
- Closed Loop Hot Oil System
- Completely Insulated & Weatherproof
|
HE-900-2P HOT OIL HEATER
|
THERMAFLOW 2000
- 1, 1.5, and 2 Million BTU Capacity Helical Coil Oil Heater.
- Compace Design for Gooseneck Applications
- Closed Loop Hot Oil Circulation System
- 100 Gallon Expansion Tank, 15 HP Circulation Pump, 2
High Limit Controls, One Oil Temperature Control, Pressure
Differential, 2 Pressuer Gauges, 2 Thermometers, and Hot
Oil Pressuer Relief Bypass Valve, to Insure Proper Oil Flow,
are Standard Safety Features
- #2 Fuel Oil Fired UL Approved Burner Standard, with Natural
Gas and Combination Burners Optional
- 3/8 Steel Shell, Insulated Internally with 2400
Degree Inswool
- 2 Seamless Pipe Coil, Incorporating a Two Pass
Heat Exchange Chamber.
|
COMBUSTION PACKAGES
BULK-THERM HEATED STORAGE TANK
REDUCED HEATING COSTS
The DIRECT FIRE Heating system is the most fuel effective method
to heat liquid asphalt, emulsions, or water. Our I-O-T Burner and
CLOVERLEAF SUPERCHARGER produce near 90% combustion efficiency and
ensure complete burning of the fuel. Model BT-30 (30,000 gallons)
will consume approximately 7 gallons of fuel oil per day!
UNIQUE REDESIGN REDUCES HEAT LOSS
Heat normally lost to the atmosphere from a hot oil heater is "a
problem solved" with the Infern-O-Therm System. This is because
the heating unit is incorporated into the insulated tank--so radiated
heat is contained in the system.
BULKTHERM TANK SPECIFICATIONS
|
Model |
Height |
Width |
Length |
Weight |
Tank Size |
Burner# |
Fuel GPH |
BTU's Input |
Tube Diameter |
CO2 |
Bacharach Smoke Scale |
|
BT 75SM |
8'9" |
8' |
26' |
6.0 Tons |
7,500 Gals. |
48/13 |
2.25 |
310,500 |
10" |
12-13% |
0.1 |
|
BT 10SM |
8'9" |
8' |
34' |
8.0 Tons |
10,000 Gals. |
48/13 |
2.25 |
310,500 |
10" |
12-13% |
0.1 |
|
BT 15SM |
11'8" |
11'0" |
26' |
9.5 Tons |
15,000 Gals. |
48/100 |
3.00 |
414,000 |
12" |
12-13% |
0.1 |
|
BT 20SM |
11'8" |
11'0" |
34' |
11.5 Tons |
20,000 Gals. |
48/100 |
3.00 |
414,000 |
12" |
12-13% |
0.1 |
|
BT 25SM |
11'8" |
11'0" |
42' |
14.0 Tons |
25,000 Gals. |
48/100 |
3.00 |
414,000 |
12" |
12-13% |
0.1 |
|
BT 30SM |
11'8" |
11'0" |
50' |
17.3 Tons |
30,000 Gals. |
48/100 |
3.00 |
414,000 |
12" |
12-13% |
0.1 |
COIL TANKS
Tank sizes ranging from 10,000 gallons to 35,000 gallon. All coil
tanks come equipped
with 2" seamless pipe coil, solenoid valve, CI "Y" Strainer,
dial thermometer & Infern-O-Therm temperature control. Vertical
& Horizontal tanks available.

Infern-O-Therm 30,000 Gallon Vertical Asphalt Storage
Tank
10,000
Gal. Vertical Fuel Oil Tank


Infern-O-Therm Factory
|